CLU-IN Home

U.S. EPA Contaminated Site Cleanup Information (CLU-IN)


U.S. Environmental Protection Agency
U.S. EPA Technology Innovation and Field Services Division

For more information on Thermal Treatment - In Situ, please contact:

Jim Cummings
Technology Assessment Branch

PH: 202-566-0868 | Email: cummings.james@epa.gov



In Situ Thermal Treatment Site Profile Database

Confidential Chlorinated Solvent Site, California
Last Updated: 01/18/2006
blue divider

Site Information                                                  
Site Name   Confidential Chlorinated Solvent Site, California
Site Location   CA
EPA Region   Region 9
Last update of database   01/18/2006
Project completion date   11/30/2005

Media Information                                               
Volume of Media Treated   8000
Geology/Hydrogeology Information                   
Presence of fractured rock in target zone?   No
Contact Information                                            
First & Last Name   Ralph Baker
CEO & Technology Manager
TerraTherm, Inc.
10 Stevens Road, Fitchburg, MA 01420
Tel.: (978) 343-0300
Fax: (978) 343-2727
Email: rbaker@terratherm.com
Performance Information                                    
Were cleanup goals and objectives met?   No
Was a microbial impact study conducted?   No
Rebound data available?   No
Information available about residual plume?   No
Effluent monitoring data available?   No
Air emissions monitoring data available?   No
Conductive Heating (In Situ Thermal Treatment) Design Elements
Comments   Thermal treatment zone is both above and below the water table, and extends to 37 ft depth.

Top of Page

For more information on Thermal Treatment - In Situ, please contact:

Jim Cummings
Technology Assessment Branch