sun

Go to Seminar

Links to Additional Resources

CLU-IN Studio
United States Environmental Protection Agency
Triad Month Session 6: Triad Case Studies
Sponsored by: U.S. EPA Technology Innovation and Field Services Division
Original Time/Date of Presentation:

August 20, 2009, 11:30 AM - 1:30 PM, EDT (15:30-17:30 GMT)


You may also be interested in the following related archives:

Presentation Overview:

A little over a year ago, over 260 individuals gathered from the U.S. and abroad at UMass-Amherst in Massachusetts to discuss the use of the Triad Approach to conduct investigations and remedial actions faster, better, and at a reduced cost. The Triad Community of Practice (CoP) decided to update and repackage several of those same sessions to benefit the greater CLU-IN audience that either may not have been able to attend the conference, or were not able to attend a specific presentation while at the conference. By doing this, we hope you too can learn more about some of the Triad tools and how they have been applied by your colleagues in the environmental industry.

Today's session is the sixth in a series of seven sessions collectively comprising Triad Month on CLU-IN. During this two-hour session, two Triad practitioners will present case studies of the Triad approach. In the first case study, "Characterizing a Complex TCE Groundwater Plume, Eliminating Suspected Source Areas, and Reducing Investigation Costs for a RCRA RFI at Shaw AFB, SC," Jonathan Shireman of Shaw Environmental & Infrastructure, will demonstrate how the Triad approach was successfully used to complete a RCRA Facility Investigation in a complex geologic setting with highly sensitive land use at Shaw Air Force Base. For the second case study, Kym Takasaki with the U.S Army Corp of Engineers, will present a case study on "Using Environmental Visualization System (EVS) Modeling to Develop Remediation Alternatives."

See also the calendar for August 2009 at CLU-IN (http://www.clu-in.org/training/) for more details about all seven sessions being offered during Triad Month.

Presentation Abstracts:

Characterizing a Complex TCE Groundwater Plume, Eliminating Suspected Source Areas, and Reducing Investigation Costs for a RCRA RFI at Shaw AFB, SC
Jonathan Shireman, PG, Shaw Environmental & Infrastructure, Inc., (Presenter). Paper authors also include Randal L. Rogers, Jr., Gas Environmental Services, and Jody Edwards, PG, Stone Environmental, Inc.

The Triad Approach was successfully used to complete a RCRA Facility Investigation (RFI) in a complex geologic setting with highly sensitive land use. Low concentrations of TCE were discovered in a deep drinking water aquifer beneath the active airfield during investigation of a fuel leak in the water table aquifer at Shaw AFB. An RFI was initiated to identify sources and to define the extent of contamination in the lower drinking water aquifer. The Triad Approach ensured a timely and efficient investigation, providing a flexible and robust plume delineation, and identification and characterization of sources.

Systematic planning meetings included South Carolina DHEC, USAF Air Combat Command, USACE Omaha District, Shaw E&I, and Stone Environmental. An open, cooperative effort yielded consensus on the use of Triad, Triad Team members, and industrial reuse criteria. The Triad Team developed an initial conceptual site model (CSM), project and data quality objectives (DQOs), and dynamic decision logic. Real-time measurement technologies and data visualization tools were used during the fieldwork to rapidly obtain and communicate data to the Triad Team, and reach consensus on critical decision points using established decision logic. The Triad Team interacted effectively with Shaw AFB Airfield Managers to mitigate safety concerns while working on the active flight line.

The dynamic work strategy performed vertical groundwater profiling to establish distributions of relative hydraulic conductivity (Ik) and contaminant concentrations. Onsite analysis of VOCs provided defensible quality data for near real-time decisions on subsequent sampling locations. Suspected source area soils were sampled for confirmation. The plume was adaptively tracked to its actual source and delineated to its downgradient extent. Daily electronic data deliverables (EDDs) and profiling hydrostratigraphic data were uploaded into ArcView IMS and posted on a project web-portal; providing timely 3-dimensional interactive viewing of the developing TCE plume to all stakeholders. Frequent Triad Team teleconferences addressed findings, next steps and site conclusions

In a three-phase, single mobilization field effort over a 9-month period, the team successfully identified the actual source area, delineated the vertical and lateral extent of the TCE plume in two separate aquifers, and revealed that six suspected source areas were benign. Based on this delineation, eight shallow and 24 deep monitoring wells were then installed.

Field analytical quality, team cooperation and well-managed uncertainty resulted in an estimated savings of up to $1.5M in investigations cost. This savings was largely realized by a dynamic work strategy and sampling methods that allowed rapid plume delineation, and an agreed upon decision logic and DQOs for determining when delineation was complete and for siting the monitoring well network, eliminating the need for subsequent investigation phases.

Using Environmental Visualization System (EVS) Modeling to Develop Remediation Alternatives
Kym Takasaki, USACE, Seattle District

The Well 12A Superfund site in Tacoma, WA encompasses the source of contamination at the property of the former Time Oil Company and the City of Tacoma's production Well 12A. The contaminants of concern in soil and ground water are tetrachloroethane (PCA), tetrachloroethene (PCE), trichloroethene (TCE), trans-1,2-dichloroethene (DCE), and other VOCs. In addition, residual NAPL and soil concentrations exceeding human health standards also remain in place. Several remedial actions have been implemented since 1988, including groundwater extraction and treatment, excavation, and soil vapor extraction. However, no detailed conceptual site model had been constructed to evaluate the effectiveness of the remedies. This case study serves as an example of how 3-D analysis of existing data sets can be used during long-term systems optimization. To aid in review of the remedy, a conceptual site model was developed using geostatistical 3-D data analysis/visualization (EVS) to help visualize present site conditions. These visualizations were then used during systematic planning sessions to identify both specific contaminant areas requiring additional treatment and site conditions that will impact treatment choices. These activities resulted in a clearly communicated proposed plan that will lead to additional treatment at the site and development of explicit remedial action objectives.

Presenters: Moderators:
Go to Seminar

Press the "Go to Seminar" button to view the seminar. Please be at this location at the beginning of the conference call.

Download Seminar For Future Reference

An archive of this seminar is available for download in Microsoft PowerPoint Format, Adobe Acrobat, and MP3 formats.
These links open in a pop-up window. You may need to turn off any pop-up blockers or add *clu-in.org to your list of allowed sites for pop-ups.

After the seminar is complete, please view:



Produced by the U.S. EPA, Technology Innovation and Field Services Division
Questions about our Internet Seminars? | Technical problems?
Rehabilitation Act Notice for Reasonable Accommodation, Webinar Recording, and Content Disclaimer

Technology Innovation Program U.S. Environmental Protection Agency