Cost and Performance
Report:
|
Preparation of this report has been funded wholly or in part by the U.S. Environmental Protection Agency under Contract Number 68-W3-0001. It has been subject to administrative review by EPA headquarters and Regional staff and by the technology vendor. Mention of trade names for commercial products does not constitute endorsement or recommendation for use.
This report presents cost and performance data for a thermal desorption treatment application at the Anderson Development Company (ADC) site located in Adrian, Lewanee County, Michigan. Between 1970 and 1979, the ADC site was used for the manufacture of 4,4-methylene bis(2-chloroaniline) or MBOCA, a hardening agent used in plastics manufacturing. Process wastewaters were discharged to an unlined lagoon. A subsequent remedial investigation determined that soil and sludges in and around the lagoon were contaminated and contaminated soils and sludges were excavated, dewatered, and stockpiled. A Record of Decision (ROD), signed in September 1991, specified thermal desorption as the remediation technology for the excavated soil. Soil cleanup goals were established for MBOCA and specific volatile and semivolatile organic constituents.
Thermal desorption using the Roy F. Weston LT3® system was performed from January 1992 to June 1993. The LT3® thermal processor consisted of two jacketed troughs, and operated with a residence time of 90 minutes and a soil/sludge temperature of 500-530°F in this application. Hollow-screw conveyors moved soil across the troughs, and acted to mix and heat the contaminated soil. The thermal processor discharged treated soil to a conditioner where it was sprayed with water. Thermal desorption achieved the soil cleanup goals specified for MBOCA and all volatile organic constituents. Seven of eight semivolatile organic constituents met cleanup goals; analytical problems were identified for bis(2-ethylhexyl)phthalate.
Information on costs for this application were not available at the time of this report. Originally, the treated soils were to be used as backfill for the lagoon. However, the state required off-site disposal of treated soils due to the presence of elevated levels of manganese.
Table of Contents | Forward to Site Information
Anderson Development Company
Adrian, Michigan
CERCLIS #: MID002931228
ROD Date: September 30, 1991
Type of Action: Remedial
Treatability Study Associated with Application? Yes (see Appendix A)
EPA SITE Program Test Associated with Application? Yes (see Reference
9)
Operating Period: 1/92 - 6/93
Quantity of Material Treated During Application: 5,100 tons of soil and
sludge
Historical Activity That Generated Contamination at the Site:
Chemical Manufacturing - plastics hardener
Corresponding SIC Code: 2869 (Industrial Organic Chemicals, Not Elsewhere
Classified)
Waste Management Practices That Contributed to Contamination: Surface
Impoundment/Lagoon
Site History: The Anderson Development Company
(ADC) is a specialty chemical manufacturer located in Adrian, Lewanee County,
Michigan, as shown on Figure 1. The ADC site covers approximately 12.5 acres of
a 40-acre industrial park. Residential areas surround the industrial park.
Figure 2 shows a layout of the ADC site.
Figure 1. Site Location [1]
Figure 2. Site Layout (adapted from [1])
Between 1970 and 1979, ADC manufactured 4,4-methylene bis(2-chloroaniline), or MBOCA. MBOCA is a hardening agent used in the manufacture of polyurethane plastics. As part of the manufacturing process, process wastewaters containing MBOCA were discharged to an unlined 0.5-acre lagoon.
In May 1986, Anderson Development Company (ADC) entered into an Administrative Order by Consent with EPA to conduct a Remedial Investigation/Feasibility Study (RI/FS). The remedial investigation determined that soil and sludge in and around the lagoon were contaminated, and contaminated soils and sludges were excavated, dewatered, and stockpiled.
Regulatory Context: A 1990 ROD selected in situ vitrification (ISV) as the remediation technology. An amended ROD was issued in September 1991 which specified thermal desorption as the remediation technology, with ISV as a contingent remedy if thermal desorption was found to be not effective. In August 1991, ADC signed a consent decree to conduct a Remedial Design/ Remedial Action (RD/RA) to remediate the site according to the specifications in the 1991 Record of Decision (ROD).
Remedy Selection: Thermal desorption was selected
based on a review of the results from a bench-scale thermal desorption study.
The performance data from the bench-scale test indicated that thermal
desorption was capable of meeting the MBOCA cleanup levels. Additionally, the
costs projected for thermal desorption treatment were lower than costs
projected for other technologies.
Site Management: PRP Lead
Oversight: EPA
Remedial Project Manager:
Jim Hahnenburg (HSRW-6J)
U.S. EPA Region 5
77 West Jackson Boulevard
Chicago, IL 60604
(312) 353-4213
State Contact:
Brady Boyce
Michigan Department of Natural Resources
Knapps Office Centre
P.O. Box 30028
Lansing, MI 48909
(517) 373-4824
Treatment System Vendor:
Michael G. Cosmos
Weston Services
1 Weston Way
West Chester, PA 19380
(610) 701-7423
Back to Executive Summary
| Table of Contents |
Forward to Matrix Description
Type of Matrix Processed Through the Treatment System: Soil (ex situ)/Sludge (ex situ)
Primary Contaminant Group: Halogenated and nonhalogenated volatile organic compounds and polynuclear aromatic hydrocarbons
The contaminants in the lagoon area identified during the remedial investigation included volatile organic compounds (VOCs), phthalates, phenols, and polynuclear aromatic hydrocarbons (PAHs). 4,4-Methylene bis(2-chloroaniline) (MBOCA) was identified as the primary constituent of concern. Other VOCs present included toluene and degradation products of MBOCA. High levels of metals (e.g., manganese at levels up to 10%) were also present at the site. [1,2]
Listed below in Table 1 are the major matrix characteristics affecting cost or performance for this technology.
Table 1. Matrix Characteristics [9]
Parameter | Value | Measurement Procedure |
---|---|---|
Soil Classification | A-7-6 Soil Group | ASTM (no further description available at this time) |
Clay Content and/or Particle Size Distribution | Arithmetic mean diameter of untreated sludge was 765 microns | Not available |
Moisture Content | Soil: Not Available Sludge: 65-70% (before dewatering) Sludge: 41-44% (after dewatering) |
Not available |
pH | <7 (before
dewatering) 10.9-11.2 (after dewatering) |
Not available |
Oil and Grease or Total Petroleum Hydrocarbons | Not available | - |
Bulk Density | Not available | - |
Lower Explosive Limit | Not available | - |
Back to Site Information | Table of Contents | Forward to Treatment System Description
Thermal Desorption
Pretreatment (Solids): Shredding/Screening/Dewatering
Post-Treatment (Air): Baghouse, Condenser, Carbon
Post-Treatment (Water): Oil-Water Separator, Filter, Carbon Adsorber
The following treatment technology description is an excerpt from the Applications Analysis Report [9]:
"The LT3® system consists of three main treatment areas: soil treatment,
emissions control, and condensate treatment. A block flow diagram of the system
[see Figure 3] is described below.
Figure 3. LT3® System Block Flow Diagram
[9]
Soil is treated in the LT3® thermal processor. The thermal processor consists of two jacketed troughs, one above the other. Each trough houses four intermeshed, hollow-screw conveyors. A front-end loader transports feed soil (or sludge) to a weigh scale before depositing the material onto a feed conveyor. The feed conveyor discharges the soil into a surge hopper located above the thermal processor. The surge hopper is equipped with level sensors and provides a seal over the thermal processor to minimize air infiltration and contaminant loss. The conveyors move soil across the upper trough of the thermal processor until the soil drops to the lower trough. The soil then travels across the processor and exits at the same end that it entered. Hot oil circulates through the hollow screws and trough jackets and acts as a heat transfer fluid. During treatment in the processor, each hollow-screw conveyor mixes, transports, and heats the contaminated soil. The thermal processor discharges treated soil into a conditioner, where it is sprayed with water to cool it and to minimize fugitive dust emissions. An inclined belt conveys treated soil to a truck or pile.
A burner heats the circulating oil to an operating temperature of 400 to 650°F (about 100°F higher than the desired soil treatment temperature). Combustion gases released from the burner are used as sweep gas in the thermal processor. A fan draws sweep gas and desorbed organics from the thermal processor into a fabric filter. Dust collected on the fabric filter may be retreated or drummed for off-site disposal. Exhaust gas from the fabric filter is drawn into an air-cooled condenser to remove most of the water vapor and organics. Exhaust gas is then drawn through a second, refrigerated condenser, which lowers the temperature further and reduces the moisture and organic content of the off-gases. Electric resistance heaters then raise the off-gas temperature back to 70°F. This temperature optimizes the performance of the vapor-phase, activated carbon column, which is used to remove any remaining organics. At some sites, caustic scrubbers and afterburners have been employed as part of the air pollution control system, but they were not used at the ADC site.
Condensate streams from the air-cooled and refrigerated condensers are typically treated in a three-phase, oil-water separator. The oil-water separator removes light and heavy organic phases from the water phase. The aqueous portion is then treated in the carbon adsorption system to remove any residual organic contaminants; after separation and treatment, the aqueous portion is often used for soil conditioning. The organic phases are disposed of off site. When processing extremely wet materials like sludge, the oil-water separation step may not be appropriate due to the high volume of condensate generated. In such cases, aqueous streams from the first and second condensers may be pumped through a disposable filter to remove particulate matter prior to carbon adsorption treatment and off-site disposal."
System Operation [2]
At ADC, contaminated soil and sludge were excavated and screened. Additionally, sludges were dewatered with a filter press to reduce the moisture content to levels sufficient for thermal treatment. The soil and dewatered sludge were then stockpiled in the feed soil staging building prior to thermal treatment. No information is available at this time on the disposition of water extracted by the filter press.
Treated soils, sludges, and fly ash were sent off-site for disposal at the Laidlaw Landfill, a Type II facility located in Adrian, Michigan. The ROD originally called for backfilling the excavated lagoon with the treated soil, sludge, and fly ash. However, due to high manganese levels, off-site disposal was required. Second-time fly ash, which is fly ash generated during the treatment of fly ash through the LT3® system, did not meet the established guidelines, and could not be disposed in the landfill. Instead, the second-time fly ash was barreled and incinerated at Petrochem Processing, Inc. in Detroit, Michigan.
Table 2 lists the major operating parameters affecting cost or performance for this technology and the values measured for each.
Table 2. Operating Parameters* [9]
Parameter | Value |
---|---|
Residence Time | 90 minutes |
System Throughput | 2.1 tons/hr |
Temperature (Soil/Sludge) | 500° -530° F |
*Values reported during SITE Demonstration.
A timeline of key activities for this application is shown in Table 3.
Table 3. Timeline [2]
Start Date | End Date | Activity |
---|---|---|
- | 5/86 | Administrative Order by Consent entered by PRP to conduct RI/FS |
- | 8/91 | Administrative Order by Consent entered by PRP to conduct RD/RA |
- | 9/8/83 | Site Placed on NPL |
- | 9/28/90 | ROD signed |
- | 9/30/91 | ROD amendment signed |
- | 9/91 | Thermal Desorption Treatability Study conducted |
9/91 | - | Contract led to Weston Services for site remediation |
10/91 | - | LT³® mobilized to Anderson Development Company Site |
11/91 | 12/91 | Dewatering activities for high water content sludges |
11/91 | - | 1st LT³® Operations test (delayed due to transportation problems) |
12/91 | - | 2nd LT³® Operations test (required because results from 1st test were destroyed in a fire) |
12/91 | - | Results from 2nd LT³® Operations test received |
1/92 | - | LT³® Operations started |
5/92 | - | LT³® operations stopped to assess operability of the process and to review potential problems with the analytical method for MBOCA |
6/92 | 8/92 | Evaluation of QAPP, resampling of treated materials, evaluation of operating temperatures via pilot plant test |
9/92 | - | Restart of LT³® operation |
6/93 | - | LT³® operations complete |
10/93 | - | LT³® removed from site |
3/24/93 | - | Memo from MDNR to EPA indicating that all ARARs have been achieved and delisting process can proceed |
Back to Matrix Description | Table of Contents | Forward to Treatment System Performance
The Consent Decree and ROD amendment identified cleanup goals for volatile organic compounds (VOCs) and semivolatile organic compounds (SVOCs) in treated soil and sludge, including an MBOCA cleanup standard of 1.684 mg/kg. Cleanup goals for VOCs and SVOCs in soil and sludge were identified as the Michigan Environmental Response Act (MERA) Number 307, Regulation 299.5711, Type B criteria for soil. Cleanup goals were not identified for metals. The specific constituents from the MERA 307 list with which ADC was required to comply are not available at this time. In addition, no information is shown on any air emission standards in the references available at this time. [1, 2, 6]
The cleanup goal for MBOCA, as specified in the ROD, is based on EPA guidance documentation and is based on the excess lifetime cancer risk level of 1 x 10-6.
During treatment, treated soils and sludges were placed in eight composite soil piles (piles A through H). All eight soil piles were approved by EPA for off-site disposal. Tables 4, 5, and 6 show the range of concentrations for MBOCA, VOCs, and SVOCs for piles B through G, respectively. No data are available at this time on the concentration of these items in the soils and sludges prior to treatment or on the concentrations of these contaminants in piles A or H. Table 7 shows the range of concentrations for 13 metals in treated soil piles B and G. [12]
Table 4. Range of 4,4-Methylene bis(2-chloroaniline) (MBOCA) Concentrations in Treated Soil Piles [12]
Constituent | Cleanup Goal | Pile B 9/17-11/22 |
Pile C 11/30-12/12 |
Pile D 12/13-1/7 |
Pile E 1/7-1/22 |
Pile F 1/26-2/13 |
Pile G 4/8-4/30 |
|
MBOCA (mg/kg) | 1.684 | BDL-1.63 | 0.55-1.52 | 0.28-1.66 | 0.21-1.67 | 0.36-1.60 | <0.05-1.590 |
BDL - Below Detection Limits (detection limit not reported)
Table 5. Range of VOC Concentrations in Treated Soil Piles [12]
Constituent | Cleanup Goal | PileB 9/17-11/22 |
PileC
11/30-12/12 |
PileD
12/13-1/7 |
Pile E
1/7-1/22 |
Pile F
1/26-2/13 |
PileG
4/8-4/30 |
---|---|---|---|---|---|---|---|
Acetone (µg/kg) | 14,000 | 100-5,400 | NA | 100-300 | 100-300 | 500 | 100-600 |
Benzene (µg/kg) | 20 | NA | NA | NA | NA | NA | 20 |
Methylene Chloride (µg/kg) | 100 | 10-20 | NA | 10-20 | 0-20 | 10-20 | 10-20 |
2-Butanone (µg/kg) | 8,000 | 100-200 | NA | 100 | NA | NA | 100 |
1,1,1-Trichloroethane (µg/kg) | 4,000 | NA | NA | NA | NA | 10 | NA |
Toluene (µg/kg) | 16,000 | 20-110 | NA | 20 | NA | NA | NA |
NA - Not available
Table 6. Range of SVOC Concentrations in Treated Soil Piles [12]
Constituent | Cleanup Goal | Pile B 9/17-11/22 |
Pile C 11/30-12/12 |
Pile D 12/13-1/7 |
Pile E 1/7-1/22 |
Pile F 1/26-2/13 |
Pile G 4/8-4/30 |
---|---|---|---|---|---|---|---|
Chrysene (µg/kg) | 330 | BDL (200)- BDL (1,100) | NA | NA | NA | BDL(700) BDL (5,300) | BDL (3,900)- BDL (12,000) |
Phenanthrene (µg/kg) | Not Identified | 200-300 | 300 | NA | NA | 400-1,800 | 700-3,200 |
Pyrene (µg/kg) | 4,000 | 200-300 | 200 | NA | NA | 300 | 700-2,300 |
Benzo(k)fluoranthene (µg/kg) | 330 | NA | NA | NA | NA | NA | 300 |
Phenol (µg/kg) | 80,000 | 200-14,000 | 3,300-5,700 | NA | NA | 4,700-5,900 | 300-1,000 |
Benzo(b)fluoranthene (µg/kg) | 330 | NA | NA | NA | NA | NA | 200-300 |
Fluoranthene (µg/kg) | 6,000 | 200-300 | 200 | NA | NA | 200-300 | 200-300 |
Bis(2-ethylhexyl)- phthalate (µg/kg) | 40 | 300 | NA | NA | NA | NA | NA |
Isophorone (µg/kg) | 160 | 200-600 | NA | NA | NA | NA | NA |
4-Methyl Phenol (µg/kg) | 8,000 | 600 | NA | NA | NA | NA | NA |
BDL - Below Detection LImit (value in parentheses is
reported method detection limit)
NA - Not Available
Table 7. Range of Metals Concentrations in Treated Soil Piles [12]
Constituent | Cleanup Goal | Pile B 9/17-11/22 | Pile G 4/8-4/30 |
---|---|---|---|
Antimony (mg/kg) | Not Identified | BDL-11 | 0.5-3.6 |
Arsenic (mg/kg) | Not Identified | BDL-25 | 16-31 |
Barium (mg/kg) | Not Identified | 67-110 | 61-130 |
Cadmium (mg/kg) | Not Identified | BDL-8.6 | 4.1-7.7 |
Chromium (mg/kg) | Not Identified | BDL-31 | 16-46 |
Copper (mg/kg) | Not Identified | 23-48 | 30-1150 |
Lead (mg/kg) | Not Identified | 13-39 | 26-140 |
Manganese (mg/kg) | Not Identified | 8,700-18,000 | 6,700-22,000 |
Mercury (mg/kg) | Not Identified | BDL-0.3 | <0.1-<0.2 |
Selenium (mg/kg) | Not Identified | 0.2-3.5 | <0.5-140 |
Silver (mg/kg) | Not Identified | BDL-3.4 | 1.2-3 |
Thallium (mg/kg) | Not Identified | 3-38 | 26-54 |
Zinc (mg/kg) | Not Idenified | 3.2-14,000 | 4,000-8,500 |
BDL - Below Detection Limit (detection limit not reported)
Chlorinated dibenzo-p-dioxins (CDDs) and furans (CDFs) were measured during the SITE Demonstration in the untreated and treated sludge, filter dust, liquid condensate, exhaust gas from refrigerated condenser, and stack gas. The results for 11 specific CDDs and CDFs measured in these locations are shown in Table 8. [9]
Table 8. Arithmetic Mean Concentrations of CDDs and CDFs Measured During SITE Demonstration [9]
Sampling Location | ||||||
Parameter | Untreated Sludge (ng/kg) |
Treated
Sludge (ng/kg) |
Filter Dust (ng/kg) | Liquid
Condensate (ng/kg) |
Exhaust Gas from Refrigerated Condenser (ng/dscm) | Stack Gas (ng/dscm) |
---|---|---|---|---|---|---|
2,3,7,8-TCDD | BDL | BDL | 0.1 | BDL | 0.01 | 0.001 |
TCDD | BDL | 0.987 | 6.54 | 119 | 0.137 | 0.0087 |
TCDF | BDL | 2.42 | 19.8 | 697 | 0.178 | 0.066 |
PeCDD | BDL | 0.534 | 5.98 | 60 | 0.2 | 0.0089 |
PeCDF | BDL | 0.066 | 2.49 | 47.7 | 0.14 | BDL |
HxCDD | BDL | BDL | 0.81 | BDL | 0.002 | BDL |
HxCDF | BDL | BDL | 0.5 | 2.8 | 0.0004 | 0.0003 |
HpCDD | BDL | BDL | 1.38 | BDL | 0.023 | 0.017 |
HpCDF | BDL | BDL | 0.14 | BDL | 0.005 | 0.0012 |
OCDD | 0.21 | BDL | 3.20 | BDL | 0.121 | 0.025 |
OCDF | BDL | BDL | 0.04 | BDL | 0.0067 | 0.0024 |
All CDDs and CDFs shown as Below Detection Limit (BDL)
are assigned a value of 0
Detection limits in untreated sludge ranged from 0.04 to 0.08 nanograms per
gram (ng/g). Detection limits in treated sludge ranged from 0.07 to 1.6 ng/g.
Detection limits in fabric filter dust ranged from 0.14 to 9.6 ng/g. Detection
limits in the liquid condensate ranged from 1.4 to 17 ng/L.
As shown in Tables 4, 5, and 6, MBOCA, other VOCs, and SVOCs met the cleanup goals for 6 soil piles treated, with 2 exceptions. In soil pile B, bis(2-ethylhexyl)phthalate (BEHP) was measured as 300 µg/kg, and the cleanup goal was 40 µg/kg. BEHP is a common laboratory contaminant, and its presence was attributed to analytical problems rather than presence in the treated soil. [12]
As shown in Table 6, isophorone was initially measured in soil pile B at levels ranging from 200-600 µg/kg, and the cleanup goal was 160 µg/kg. Additional samples from soil pile B showed that isophorone and other SVOCs were measured at levels below the detection limit. The RPM stated that, prior to disposal, soil at this site had to be retreated until all cleanup goals were met. Soil from pile B was disposed off site. It is not known at this time if soil from pile B that showed the elevated levels of isophorone was retreated.
As shown in Table 7, the treated soils contained concentrations of manganese ranging from 6,700 mg/kg to 22,000 mg/kg. Due to these high concentrations of manganese, ADC was required to dispose of these residuals in an off-site landfill, instead of being backfilled on site.
As shown in Table 8, dioxins and furans were present in some treatment residuals. The fabric filter dust contained the highest concentrations of dioxins/furans and was the only solid residual containing measurable amounts of 2,3,7,8-TCDD.
Data are available on the concentrations of MBOCA, VOCs, and SVOCs in six of eight treated soil piles; these data are adequate for comparison with cleanup goals. Data are also available on the concentrations of CDDs and CDFs in six sampling locations.
EPA SW-846 methods were used for sampling soil piles at ADC; no information is available at this time on the analytical methods used.
Analytical problems were identified by the PRP for chrysene, BEHP, and isophorone in soil pile B. For chrysene, analytical data sheets were identified incorrectly; problems for BEHP and isophorone are described above under "Performance Data Assessment."
Back to Treatment System Description | Table of Contents | Forward to Treatment System Cost
The PRPs contracted with nine firms to provide support services for the ADC remediation. Weston Services served as the primary contractor for soil excavation and treatment at ADC. Table 9 lists each contractor and their role in this cleanup. No information is available at this time on the competitive nature of these procurements.
Table 9. ADC Remediation and Support Contractors [2]
Contractor | Activity |
---|---|
Weston Services | Soil excavation and treatment |
Clayton Environmental Consultants | Analytical services |
Chester LabNet | Analytical services |
Laidlaw Waste Systems | Transport and disposal of treated soils, sludge, and fly ash |
Simon Hydro-Search | Environmental consultants, Project management |
OHM | Dewatering of high moisture content sludges |
Environmental Science and Engineering | Installation of groundwater monitoring wells |
Clean Harbors | Disposal of wastewater and contaminated stormwater |
Environmental Management Control, Inc. | Backfilling the excavated lagoon |
No information is available at this time on the costs for the thermal desorption treatment application at ADC.
The Applications Analysis Report [9] includes cost projections for using the LT3® system at other sites. As shown in Tables 10, 11, and 12, costs are divided into 12 categories and are reported as cost per ton of soil treated, for three different soil moisture contents. The values are based on using an LT3® system similar to the system used at the Anderson site. [9]
Table 10. Projected Costs for Activities Directly Associated with Treatment [9]
Cost Categories | Cost Per Ton of Soil Treated (dollars)a | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Soil Moisture Content | |||||||||||
20% | 45% | 75% | |||||||||
Startup/Testing/Permits Startup Costsb Mobilization Assembly Shakedown Total Startup Costs |
10.00 25.00 15.00 50.00 |
10.00 25.00 15.00 50.00 |
10.00 25.00 15.00 50.00 |
||||||||
Operation
(Short-Term - up to 3 years) Labor Costsc Operations Staff Site Manager Maintenance Supervisor Site Safety Officer Total Labor Costs |
39.00 21.60 7.20 7.20 75.00 |
79.50 44.30 14.60 14.60 153.00 |
79.50 44.30 14.60 14.60 153.00 |
||||||||
Supply and Consumable
Costs PPEc PPE Disposable Drumsc Residual Waste Disposal Drums Activated Carbone Diesel Fuelc Calibration Gasese Total Supply and Consumable Costs |
6.00 0.50 1.20 8.00 0.62 0.35 16.70 |
10.00 1.00 1.20 24.00 1.00 1.10 38.30 |
10.00 1.00 1.20 24.00 1.00 1.10 38.30 |
||||||||
Utility
Costs Natural Gas (@ $1.43/1,000 ft³) Electricity (@ $0.18/kWh) Water (@$1.00/100 gal.) Total Utility Costs |
7.80 2.10 0.60 10.50 |
26.00 6.30 0.60 32.90 |
26.00 6.30 0.60 32.90 |
||||||||
Equipment Repair and
Replacement Costs Maintenance Design Adjustmentsf Facility Modificationsf Total Equipment Repair and Replacement Costs |
11.70 0.00 0.00 11.70 |
19.80 0.00 0.00 19.80 |
19.80 0.00 0.00 19.80 |
||||||||
Cost of
Ownership Equipment Costs LT³® Rentalc Support Equipment Rental Dumpstersc Wastewater Storage Tankse Steam Cleaner Portable Toiletc Optional Equipment Rentalc Total Equipment Costs |
13.00d 0.70 1.00 0.10 0.10 12.00 26.90 |
22.00 1.35 2.00 0.10 0.20 20.00 45.65 |
22.00 1.35 2.00 0.10 0.20 20.00 45.65 |
||||||||
Total | 190.80 | 339.65 | 339.65 |
a=Cost per ton of soil treated; figures are rounded and
have been developed for a 3,000-ton project.
b=Fixed cost not affected by the volume of soil treated.
c=Costs are incurred for the duration of the project.
d=Feed rate is double that of soils with 45% moisture content.
e=Costs are incurred only during soil treatment activities.
f=Cost included in the cost of renting the LT3®
system.
Table 11. Projected Costs for Before-Treatment Activities [9]
Cost Categories |
Cost Per Ton of Soil Treated (dollars)a | ||
---|---|---|---|
Soil Moisture Content | |||
20% | 45% | 75% | |
Mobilization and Preparatory Work | |||
Site Preparation Costs | |||
Administrative Costs | 11.00 | 11.00 | 11.00 |
Fencing Costs | 0.40 | 0.40 | 0.40 |
Construction Costs | 0.70 | 0.70 | 0.70 |
Dewatering Costs | NA | NA | 187.90 |
Total Site Preparation Costs | 12.10 | 12.10 | 200.00 |
Permitting and Regulatory Costs | |||
Permit | 3.30 | 3.30 | 3.30 |
Engineering Support | 80.00 | 80.00 | 80.00 |
Total Permitting and Regulatory Support | 83.30 | 83.30 | 83.30 |
Monitoring, Sampling, Testing, and Analysis | |||
Analytical Costs | |||
Treatability Studyb | 10.00 | 10.00 | 10.00 |
Sample Analysis for VOCs | 4.20 | 12.00 | 12.00 |
Total Analytical Costs | 14.20 | 22.00 | 22.00 |
Total | 109.60 | 117.40 | 305.30 |
NA=Not Applicable
a=Cost per ton of soil treated; figures are rounded and have been developed for a 3,000-ton project.
b=Fixed cost not affected by the volume of soil treated.
Table 12. Projected Costs for After-Treatment Activities [9]
Cost Categories |
Cost Per Ton of Soil Treated (dollars)a |
||
---|---|---|---|
Soil Moisture Content |
|||
Disposal (Commercial) | 20% | 45% | 75% |
Residual Waste and Waste Shipping,
Handling, and Transportation Costs |
|||
Oversized Material (2% of feed soil) | 5.40 | 5.40 | 5.40 |
Drums | 27.00 | 27.00 | 27.00 |
Wastewater | 7.20 | 14.40 | 14.40 |
Total Residual Waste and Waste Shipping, | |||
Handling, and Transportation Costs | 39.60 | 46.80 | 46.80 |
Demobilization | |||
Site Demobilization Costs | 33.00 | 33.00 | 33.00 |
Total | 72.60 | 79.80 | 79.80 |
a=Cost per ton of soil treated; figures are rounded and have been developed for a 3,000-ton project.
The costs are shown in Tables 10, 11, and 12 according to the format for an interagency Work Breakdown Structure (WBS). The WBS specifies 9 before-treatment cost elements, 5 after-treatment cost elements, and 12 cost elements that provide a detailed breakdown of costs directly associated with treatment. Tables 10, 11, and 12 present the cost elements exactly as they appear in the WBS, along with the specific activities, and unit cost and number of units of the activity (where appropriate), as provided in the Applications Analysis Report.
Back to Treatment System Performance | Table of Contents | Forward to Observations and Lessons Learned
Back to Treatment System Cost | Table of Contents | Forward to References
This case study was prepared for the U.S. Environmental Protection Agencys Office of Solid Waste and Emergency Response, Technology Innovation Office. Assistance was provided by Radian Corporation under EPA Contract No. 68-W3-0001.
Back to Observations and Lessons Learned | Table of Contents | Forward to Appendix A - Treatability Study Results
Treatability Study Objectives
Canonie conducted a bench-scale treatability study using their Low Temperature Thermal Aeration (LTTA) process on contaminated soil from the Anderson site. The study had the following objectives [10]:
Treatability Study Test Description
The treatability study consisted of six runs. A bench-scale thermal desorption system was used during the study to simulate the full-scale LTTA system. The bench-scale system utilized a batch process, and consisted of a hollow rotating cylinder with a metal shell which simulated the rotary drum dryer in the LTTA system. The shell was heated externally, which in turn heated the soil fed into the cylinder. In the full-scale design, heat transfer is accomplished directly, and includes a continuous feed of soil.
Off-gasses from the soil were carried from the dryer by induced air flow through the rotating cylinder. Air flow was induced through the cylinder at a rate of 0.25 to 0.30 cubic feet per minute (cfm). The amount of air flow per mass of soil in the dryer was much smaller than in the full-scale unit. Because of the relatively lesser amount of particulates produced, a baghouse was not included in the design of the bench-scale unit.
The off-gasses from the bench-scale unit were first vented through a series of water cooled condensers, which simulated the Venturi scrubber in the full-scale system. This unit condensed water vapor and some volatile and semivolatile organics, including MBOCA. For the fifth and sixth run, the condenser off-gas was vented through Tenax or polyurethane foam (PUF) tubes, respectively, to sample for volatile or semivolatile compounds which remained in the off-gas. This measured the amount of volatiles and semivolatiles which would enter the vapor phase carbon unit in the full-scale system.
The first four runs of the treatability study were preliminary runs, while the last two were system optimization runs. Canonie performed the runs on contaminated sludge and clay from the Anderson site. The clay was shredded to a particle size of less than one-half inch and then dried. The procedure used for the treatability study follows:
Treatability Study Performance Data
Untreated and treated soil samples from each run were analyzed for MBOCA. The operating parameters and the MBOCA data for the six runs are presented in Table A-1. The results show that runs with a bed temperature of greater than 600°F (runs 1 and 2) had a removal efficiency of greater than 99.99%, removing MBOCA to concentrations of less than 0.05 mg/kg. Runs 3 and 4 showed that when the bed temperature was below 600°F and untreated soil concentrations were relatively high (300 mg/kg or higher), large concentrations of MBOCA remained in the treated soils.
Samples from Runs 5 and 6 were analyzed for concentrations of volatile and semivolatile organics. The results, shown in Table A-2, show that volatile and semivolatile soil concentrations were relatively low before treatment, and that the technology reduced concentrations of toluene. Other compounds showed no decrease or an increase in concentration. Results of the condensate analysis are presented in Table A-3.
Results of the off-gas analysis show that no semivolatiles were present and only low levels of volatiles were present. Of the volatiles, acetone and acetaldehyde were present at the greatest concentrations, at 20 µg/kg and 6 µg/kg, respectively. The off-gas analytical data is presented in Table A-4. [10]
Canonie estimated that they could perform the full-scale remediation for a fixed price of $810,000. This estimate was based on a maximum of 2,000 tons of soil. This estimated cost does not include site preparation, electrical costs, or waste disposal.
Table A-1. MBOCA Concentrations in Pre- and Post-Treatment Soil and Relative Test Run Conditions
Test Run No. |
MBOCA (mg/kg) | Percent Reduction in MBOCA | Test Run Conditions | ||
---|---|---|---|---|---|
Pretreatment | Post- Treatment |
Median Bed Temperature (F°) |
Run Time (min) | ||
1 | 570 | <0.05 | 99.99 | 700 | 10 |
2 | 1100 | <0.05 | 99.99 | 600 | 10 |
3 | 300 | 13 | 95.67 | 500 | 12.5 |
4 | 320 | 240 | 25 | 480 | 12.5 |
5 | 9.2 | <0.05 | 99.45 | 520 | 12.5 |
6 | 81 | 0.23 | 99.72 | 520 | 10.0 |
Table A-2. Summary of Volatile and Semivolatile Organics in Pre- and
Post-Treatment Soil
Test Run No. | Compound Detected | Concentration (µg/kg) | |
---|---|---|---|
Pretreatment Sample | Post-Treatment Sample |
||
5 | Volatiles | ||
Acetone | 1,900 | 1,900 | |
Benzene | ND | 8 | |
Chlorobenzene | 40 | ND | |
Methyl Chloride | ND | 58 | |
Tetrachloroethene | 40 | ND | |
Toluene | 1,800 | 54 | |
Xylenes (Total) | 40 | 5 | |
Semivolatiles | |||
Bis(2-ethylhexyl)phthalate | 1,000 | 1,200 | |
4-Methylphenol | 2,600 | 2,100 | |
6 | Volatiles | ||
Acetone | ND | 2,600 | |
Benzene | ND | 12 | |
Methyl Chloride | ND | 200 | |
Toluene | 720 | 98 | |
Xylenes (Total) | ND | 12 | |
Semivolatiles | |||
Bis(2-ethylhexyl)phthalate | 1,200 | ND | |
4-Methylphenol | 2,100 | ND |
ND - Not detected
Table A-3. Summary of Volatile and Semivolatile Organics In Condenser Off-Gas
Test Run No. | Compound Detected | Concentration (µg/kg) |
---|---|---|
5 | Volatiles Only* | |
C4H8 Hydrocarbon | 0.2 | |
Acetaldehyde | 6 | |
C5H10 Hydrocarbon | 0.1 | |
C5H12 Hydrocarbon | 0.07 | |
C5H8 Hydrocarbon | 0.08 | |
Furan | 0.08 | |
Carbon Disulfide | 0.7 | |
Propanol | 3 | |
Acetone | 20 | |
C6H12 Hydrocarbons | 0.9 | |
Acetonitrile | 0.3 | |
C6H14 Hydrocarbons | 3 | |
Methyl Acetate | 0.2 | |
Methyl Propanol + C6H12 Hydrocarbon | 0.8 | |
Methyl Propanol | 0.1 | |
C6H10 Hydrocarbon + C6H12 Hydrocarbon | 0.07 | |
Unknown Compound | 0.08 | |
Butanol | 0.9 | |
Unknown Compound | 0.03 | |
6 | Semivolatiles Only* | |
None Detected | - |
*The GC column was not heated during VOC analyses, hence the list presented may not include all the volatile compounds present in the sample.
Table A-4. Summary of Condensate Analyses
Compound Detected | Concentration |
---|---|
MBOCA | 860 |
Volatiles | |
Acetone | 30,000 |
Toluene | 600 |
Acetaldehyde | 1,000 |
Methyl Ester of Methyl Propeonic Acid | 300 |
Semivolatiles | |
4-Chloroaniline | 1,500 |
4-Methylphenol | 12,000 |
Phenol | 5,100 |
Aniline | 20,000 |
Pyridine | 800 |
Furancarboxaldehyde | 900 |
Dimethyl Pyridine | 800 |
Benzaldehyde | 2,000 |
Bromophenol + Acetophenone | 900 |
Chloroaniline Isomer | 200,000 |
Benzothiazole | 1,000 |
Chloromethyl Benzeneamine | 1,000 |
Bromophenol | 900 |
Unknown Nitrogen Compound | 1,000 |
Dibromophenol | 3,000 |
Chloro Methoxy Pyrimidinamine | 8,000 |
Unknown Nitrogen Compound | 3,000 |
Treatability Study Lessons Learned