For more information on Thermal Treatment - In Situ, please contact:
In Situ Thermal Treatment Site Profile Database
Alhambra Pole Yard
Last Updated: 01/18/2006 | ||
| ||
Site Information | ||
Site Name | Alhambra Pole Yard | |
Site Location | Alhambra, CA | |
EPA Region | Region 9 | |
Last update of database | 01/18/2006 | |
Beginning of construction/installation phase | 02/01/2001 |
Media Information | ||
Volume of Media Treated | 16200 | |
Comments | Treatment includes both soil, silty sand and debris | |
Geology/Hydrogeology Information | ||
Depth to water table | > 240 feet bgs | |
Presence of fractured rock in target zone? | No | |
Contact Information | ||
First & Last Name | Ralph Baker CEO & Technology Manager TerraTherm, Inc. 10 Stevens Road, Fitchburg, MA 01420 Tel.: (978) 343-0300 Fax: (978) 343-2727 Email: rbaker@terratherm.com |
|
Performance Information | ||
Were cleanup goals and objectives met? | Yes | |
Was a microbial impact study conducted? | No | |
Rebound data available? | No | |
Information available about residual plume? | No | |
Effluent monitoring data available? | No | |
Air emissions monitoring data available? | No | |
Conductive Heating (In Situ Thermal Treatment) Design Elements | ||
Number of heating wells | 785 | |
Average distance between heating wells | 7 | |
Units for distances between heating wells | feet | |
Maximum soil temperature achieved | 635 | |
Units for maximum soil temperature | Fahrenheit | |
General description | The In Situ Thermal Destruction remediation at the Alhambra facility includes the following additional design features: Insulated surface seal, thermal oxidizer, heat exchanger, and granular activated carbon (GAC) for off-gas treatment. |
For more information on Thermal Treatment - In Situ, please contact: