In-well vapor stripping technology involves the creation of a ground-water circulation pattern and simultaneous aeration within the stripping well to volatilize VOCs from the circulating ground water. Air-lift pumping is used to lift ground water and strip it of contaminants. Contaminated vapors may be drawn off for aboveground treatment or released to the vadose zone for biodegradation. Partially treated ground water is forced out of the well into the vadose zone where it reinfiltrates to the water table. Untreated ground water enters the well at its base, replacing the water lifted through pumping. Eventually, the partially treated water is cycled back through the well through this process until contaminant concentration goals are met. |