In Situ Thermal Treatment Site Profile Database

Unknown, Southeastern U.S.
Last Updated: 10/28/2009
blue divider

Site Information                                                  
Site Name   Unknown, Southeastern U.S.
Site Location  
Last update of database   10/28/2009

Geology/Hydrogeology Information                   
Depth to water table   55 feet below ground surface
Presence of fractured rock in target zone?   Yes
Contact Information                                            
First & Last Name   Ralph Baker
CEO & Technology Manager
TerraTherm, Inc.
10 Stevens Road, Fitchburg, MA 01420
Tel.: (978) 343-0300
Fax: (978) 343-2727
Email: rbaker@terratherm.com
Performance Information                                    
Were cleanup goals and objectives met?   Yes
Was a microbial impact study conducted?   No
Rebound data available?   No
Information available about residual plume?   No
Effluent monitoring data available?   No
Air emissions monitoring data available?   No
Lessons Learned                                                 
Lessons learned   Lessons learned include creating a “hot floor” at 90 feet within the upper portion of the bedrock to achieve a 95% UCL less than 60 ug/kg as well as creating an upward hydraulic gradient between bedrock and unconsolidated soils so that mobilized DNAPL was unable to migrate vertically into the bedrock.