State Coalition for Remediation of Drycleaners Site Profiles
Joyce Cleaners, Farmers Branch, Texas
Description
|
Joyce Cleaners facility is a leased space within a multi-tenant commercial retail strip center. The affected properties include both on- and off-site properties. Joyce Cleaners is currently in operation and is identified as using PCE as its drycleaning solvent. Remediation Status: Site closed |
Contaminants
Contaminants present and the highest amount
detected in both soil and groundwater.
Contaminant | Media | Concentration (ppb) | Nondetect |
---|---|---|---|
trans-1,2-Dichloroethene | groundwater | 15 ppb | |
trans-1,2-Dichloroethene | soil | 530 ppb | |
cis-1,2-Dichloroethene | groundwater | 1,600 ppb | |
cis-1,2-Dichloroethene | soil | 2,900 ppb | |
Tetrachloroethene (PCE) | groundwater | 230 ppb | |
Tetrachloroethene (PCE) | soil | 560 ppb | |
Trichloroethene (TCE) | groundwater | 28 ppb | |
Trichloroethene (TCE) | soil | 340 ppb | |
Vinyl Chloride | groundwater | 310 ppb | |
Vinyl Chloride | soil | 1,800 ppb |
Site Hydrology
Deepest Significant Groundwater Contamination: | 20ft bgs | |
Plume Size: | Plume Length: 550ft Plume Width: 100ft |
|
Average Depth to Groundwater: | 10ft |
Lithology and Subsurface Geology
Gravelly sand fill with pockets of clay Depth: 0-2.5ft bgs 2.5ft thick Gradient: 0.001ft/ft |
||
Silty/sandy clay Depth: 2.5-10ft bgs 7.5ft thick Gradient: 0.001ft/ft |
||
Gravel/silty sand Depth: 10-20ft bgs 10ft thick Gradient: 0.001ft/ft |
||
Clay Depth: 20-25ft bgs 5ft thick Gradient: 0.001ft/ft |
Pathways and DNAPL Presence
Groundwater Sediments Soil DNAPL Present |
Vapor Intrusion Pathway
Has the potential for vapor intrusion (VI) been evaluated? |
No |
|
Has a vapor mitigation system been installed? |
Remediation Scenario
Cleanup
Goals: |
Reduce COC levels below MCLs |
|
Remedy Level: |
Interim Action |
Technologies
In Situ Biostimulation |
Why the technology was selected: Date implemented: Final remediation design: Results to date: Cost to Design and Implement: |
|
In Situ Chemical Oxidation |
Why the technology was selected: Date implemented: Final remediation design: Results to date: Cost to Design and Implement: |
Costs
Cost
for Assessment: |
$99,593.16 | |
Cost
for Operation and Maintenance: |
||
Total
Costs for Cleanup: |
Contacts
David Cullen Project Manager Texas Commission on Environmental Quality PST/DCRP Section, Remediation Division, MC-137 P.O. Box 13087 Austin, TX 78711-3087 |
Site Specific References
Field Activities Report 2010 Affected Property Assessment Report 2009 |