State Coalition for Remediation of Drycleaners Site Profiles
Shorty Cleaners, Stillwater, Minnesota
Description
|
The site consists of a single story masonry building and adjacent parking lot. The site comprises approximately 13,000 square feet. The site is located in a residential/commercial area. Two dry cleaning machines are on property and PCE was the primary solvent used for the operation. The site is contaminated with both BTEX and chlorinated solvent. |
Contaminants
Contaminants present and the highest amount
detected in both soil and groundwater.
Contaminant | Media | Concentration (ppb) | Nondetect |
---|---|---|---|
Benzene | groundwater | 3.3 ppb | |
Benzene | soil | 4,000 ppb | |
sec-butylbenzene | soil | 3,700 ppb | |
cis-1,2-Dichloroethene | groundwater | 5,000 ppb | |
cis-1,2-Dichloroethene | soil | 6,100 ppb | |
ethylbenzene | groundwater | 280 ppb | |
ethylbenzene | soil | 62,000 ppb | |
n-butylbenzene | soil | 230,000 ppb | |
n-propylbenzene | soil | 150,000 ppb | |
Tetrachloroethene (PCE) | groundwater | 50,000 ppb | |
Tetrachloroethene (PCE) | soil | 1,200,000 ppb | |
p-isopropyltoluene | soil | 18,000 ppb | |
1,2,4-trimethylbenzene | soil | 95,000 ppb | |
1,3,5-trimethylbenzene | soil | 37,000 ppb | |
naphthalene | groundwater | 1,500 ppb | |
naphthalene | soil | 23,000 ppb | |
Trichloroethene (TCE) | groundwater | 5,500 ppb | |
Trichloroethene (TCE) | soil | 16,000 ppb | |
toluene | groundwater | 34 ppb | |
Vinyl Chloride | groundwater | 430 ppb | |
xylenes | groundwater | 94 ppb | |
xylenes | soil | 97 ppb |
Site Hydrology
Deepest Significant Groundwater Contamination: | ||
Plume Size: | ||
Average Depth to Groundwater: | 11ft |
Lithology and Subsurface Geology
silty sand fill Depth: 0-11ft bgs 11ft thick |
||
sand to silty sand Depth: 11-20ft bgs 9ft thick Conductivity: 3.15ft/day Gradient: 0.318ft/ft |
||
sand to silty sand with clay layers, clay layers are 0.25 to 11 inch thick Depth: 20-40ft bgs 20ft thick Conductivity: 16.8ft/day |
||
gravelly sand to sand with gravel Depth: 40-60ft bgs 20ft thick |
||
bedrock Depth: 60-120ft bgs 60ft thick |
Pathways and DNAPL Presence
Groundwater Sediments Soil DNAPL Present |
Remediation Scenario
Cleanup
Goals: |
Groundwater: Eliminate hot spot at MW-3. Soil: Reach asymptotic removal rates of VOCs for 3 consecutive quarters. |
Technologies
In Situ Chemical Oxidation |
Why the technology was selected: Date implemented: Next Steps: |
|
In Situ Monitored Natural Attenuation |
Final remediation design: Results to date: Next Steps: |
|
In Situ Soil Vapor Extraction |
Why the technology was selected: Date implemented: Final remediation design: Results to date: Next Steps: |
Costs
Cost
for Assessment: |
||
Cost
for Operation and Maintenance: |
||
Total
Costs for Cleanup: |
Contacts
Groundwater Atlas https://www.pca.state.mn.us/data/minnesota-groundwater-contamination-atl What's in My Neighborhood https://www.pca.state.mn.us/data/whats-my-neighborhood Consultant: Delta Environmental Consulting, Inc 2770 Cleveland Ave Roseville, MN 55113 651-639-9449 |
Site Specific References
1. Shorty Cleaner Launderer Environmental Assessment – Phase 2. January 15, 1996. Prepared by Delta Environmental Consulting, Inc. 2. Addendum – Phase II Report, February 25, 1997, Delta 3. Environmental Assessment – Phase 3/Response Action Plan. December 5, 1997. Prepared by Delta Environmental Consulting, Inc. 4. SVE System Installation and Startup Report, August 13, 1998, Delta 5. Ground Water Monitoring and Remediation System Closure Report, May 3, 2000, Delta. 6. GW Monitoring Report for Shorty Cleaner Launderer Site. June 25, 2001. Prepared by Delta Env. Consulting, Inc. |